CEM Specialties Inc.

Process & Emission Monitoring Specialists

 

 

Search For:


CEM Specialties Inc. 1100 Dearness Drive London, Ontario
Canada  N6E 1N9
Tel: 519-681-9595
Fax: 519-681-8799
Toll Free: 1-866-236-7732
admin@cemsi.on.ca

PRODUCTS - Particulate Monitors

Back to Products

DURAG
     D-R 300 - Soot Monitor
     D-R 300-40 - Dust Concentration Monitor
     D-R 800 - Dust Concentration Monitor
     D-RX 250 - Combined Monitor (Dust, Flow, Pressure and Temperature)
     F-904 - Beta Gauge Particulate Monitor
     F-904-K - Beta Gauge Particulate Monitor
     OF-1200 - Soot Monitor (Emission)

     OF-1200i - Soot Concentration Monitor (Ambient Air)


D-R 300 - Soot Monitor

Description: The D-R 300 works according to the back scattering principle and has been designed to monitor extremely low soot concentrations in light oil fired plants.
Applications: Measurement of lowest soot concentrations
Sensitivity: 5 g/m3
Compliance: TV approved
Measuring range: Smallest measuring range 0 3 soot number, lowest detection limit 0,005 mg/m3
Flue gas temperature: Above dew point, up to 320C, higher on request
Accuracy: < 2% FS
Measured components: Stray light intensity / soot number
Measuring principle: Back scattering 
Measuring output: 2 analog outputs 0/4...20 mA
Protection: IP 65
Ambient temperature: -20... +50C
Status/control signals: Relay outputs and potential free inputs for status signals
System components: Transmitter/Receiver unit, 2 light traps, control unit, one purge air blower
Test functions: Automatic zero and span check point
Download: DR300 Brochure


D-R 300-40 - Dust Concentration Monitor

Description: The D-R 300-40 works according to the back scattering principle and has been designed to monitor extremely low dust concentrations in various application processes like incinerators, steelworks, cement plants etc.  TV approved according to German Clean Air Act, large combustions and waste incinerators.
Applications: Measurement of lowest dust concentrations
Sensitivity: 0.01 mg/m3
Compliance: TV approved for quantitative emissions monitoring, especially for waste incinerators, GOST
Measuring range: Smallest measuring range 0...1 mg/m3, largest range 0...100 mg/m3
Flue gas temperature: Above dew point, up to 320C, higher on request
Accuracy: < 2% FS
Measured components: Stray light intensity / dust concentration
Measuring principle: Back scattering 
Measuring output: 2 analog outputs 0/4...20 mA
Protection: IP 65
Ambient temperature: -20... +50C
Status/control signals: Relay outputs and potential free inputs for status signals
System components: Transmitter/Receiver unit, light trap, control unit, one purge air blower
Test functions: Automatic zero and span check point
Download: DR300 Brochure


D-R 800 - Dust Concentration Monitor

Description: Where other technologies fail, the D-R 800 measures precisely even lowest dust concentrations by means of scattered light principle integrated into a measuring lance. Mechanical adjustment and alignment on dust free measuring section are not necessary. 
Applications: Monitoring minimal dust concentrations
Measuring range: 0...10/200 mg/m3 
Flue gas temperature: Above dew point, up to 220C, higher on request  
Accuracy: 2% of measuring range
Measured components: Stray light intensity / dust concentration in mg/m3
Measuring principle: Forward scattering 
Measuring path:  Stack wall thickness < 0.4 m
Measuring output: 0/4...20 mA analog output
Interfaces: RS 485 Modbus RTU
Protection: IP 65 
Ambient temperature: -20... +50C
Status/control signals: relay outputs and potential free inputs for status signals 
System components: Transmitter/Receiver unit, control unit, connection box with blower
Test functions: Automatic zero and span check point
Download: DR800 Brochure


D-RX 250
- Combined Monitor (Dust, Flow, Pressure and Temperature)

Description: Single-rod measurement probe for the simultaneous measurement of: Dust concentration [mg/Nm3], Volume flow [Nm3/h], Temperature [C], Absolute pressure [hPa]; Only one probe / mounting aperture in flue-gas duct Operation and evaluation unit can be connected at up to 1000 m distance via bus interface; For measurements according to the TA Luft emission standard, 13., 17. and 27. BImSchV.
Applications: Continuous measurement of dust, flow, temperature and pressure behind filtering systems
Compliance: TV approved for qualitative emissions monitoring
Measuring range: Dust concentration: 0...10 up to 0...500 mg/Nm3; Volume flow 0...999.999 Nm3/h; Temperature: 0...300C; Pressure: 900...1.300 hPa
Flue gas temperature: Above dew point, up to 200C, higher on request

Measured components:

Dust concentration in mg/m3 or mg/Nm3; Volume flow in m3/h or Nm3/h; Temperature in C; Pressure in hPa
Measuring principle: Tribo electric + differential pressure 
Measuring path:  > 0.3 m
Measuring output: 4 analog outputs 0/4...20 mA, variable assignment
Interfaces: RS485 Modbus RTU
Protection: IP 65 
Ambient temperature: -20... +50C
Status/control signals: relay outputs for status signals
System components: Probe, transmitting and operation unit and differential pressure transformer
Test functions: Automatic zero and span check point
Download: DRX250 Brochure


F-904
- Beta Gauge Particulate Monitor

Description: The F-904 is an extractive Dust Concentration Monitor for measurement/monitoring of dust concentrations in industrial plants. It has been designed especially for wet stack gases. With a heated sampling system the sample gas will be sucked and the dust sampled on a filter tape. The dilution of the sample gas allows to measure high dust concentrations.
Applications: Coal and oil fired power plants, waste incinerators and waste water sludge incinerators, measurement/monitoring of dust concentration after wet scrubbers, in very wet waste gases in other process applications, heavy metal analysis, measurement of dust concentration in a large range, sampling points on limited mounting positions and small stack diameters; Measurement of Dust Concentration in wet gases.
Sensitivity: < 0,3 mg/Nm3
Compliance: German equivalency test for all burners incl. waste incinerators, Korean MOE approved 
Measuring range: Dust concentration: 0...1 up to 0...2000 mg/Nm3 
Flue gas temperature: low (below dew point) and high temperatures 
Accuracy: 5% of measuring range
Measured components: Dust concentration in mg/Nm3, gas sample dry, temperature in C
Measuring principle: Absorption of Beta-radiation
Measuring output: Analog outputs: 4...20 mA for dust concentration (variable range assignment) and dust mass (fixed assignment)
Interfaces: Analog outputs, digital status signals (inputs, outputs) 
Protection: IP 54 
Ambient temperature: 0...50C
Status/control signals: relay outputs and inputs for status signals
System components: Sample probe, Sample line, measuring instrument 
Test functions: Automatic zero and span check point, reference foil
Download: F904 Brochure


F-904-K
- Beta Gauge Particulate Monitor

Description: The F-904's major components are housed in a sturdy cabinet and are easily accessible for periodic inspection and maintenance.  The Model F-904-K Extractive Beta Gauge Particulate Monitor is designed for a wide range of emission monitoring applications.
Applications: Coal and oil fired power plants, waste incinerators (urban, industrial and hazardous waste), waste water sludge incinerators, dust monitoring after wet scrubbers, heavy metal analysis, small diameter stack monitoring, particulate monitoring in process applications (bag houses, etc.); transportable version for mobile applications.
Download: F904K Brochure

   
OF-1200 - Soot Monitor (Emission)

Description: The OF-1200 is a Soot Meter, based on sampling of soot particles on a filter tape in a sample gas volume of an emission and measurement of optical reflection.  It has been designed to monitor soot concentrations in light oil fired plants. 
Applications: Measurement of soot concentrations in emission
Sensitivity: 0.1 RZ
Compliance: German equivalency test according to TA Luft
Measuring range: 0...3 RZ
Flue gas temperature: Low (below dew point) and high temperatures
Accuracy: < 5% of measuring range
Measured components: Smoke spot number RZ
Measuring principle: Differential optical reflection of a filter before and after sampling of soot
Measuring output: Analog output 4...20 mA for Ruzahl RZ (fixed assignment) 
Interfaces: RS 232, device interface (analog outputs, digital status inputs and outputs) 
Ambient temperature: 0...50C
Status/control signals: Relay outputs and inputs for status signals
System components: Sampling system (inlet, sample line), measuring instrument 
Test functions: Automatic zero check point, reference foil
Download: OF1200i Brochure


OF-1200i
- Soot Concentration Monitor (Ambient Air)

Description: The OF-1200i is a Soot Concentration Meter, based on sampling of soot particles on a filter tape in a sample gas volume of the ambient air and measurement of optical reflection. 
Applications: Measurement/monitoring of soot concentrations in the ambient air 
Sensitivity: < 0.2 g/m3 (1h-suck cycle)
Compliance: Conforms to TA-Luft
Measuring range: 0...360 g/m3
Flue gas temperature: Ambient temperature 
Measured components: Smoke spot number RZ
Measuring principle: Differential optical reflection of a filter before and after sampling of soot 
Measuring output: Analog output 4...20 mA for soot concentration 0...360 g/m3 (fixed assignment)
Interfaces: RS 232, device interface (analog outputs, digital status inputs and outputs)
Ambient temperature: 0...50C
Status/control signals: Relay outputs and inputs for status signals
System components: Sampling system (inlet, sample line), measuring instrument
Test functions: Automatic zero check point, reference foil
Download: OF1200i Brochure

 