Non-Heated Flow Meters:

The FM1 and FM10 are corrosion-resistant and used for controlling the flow in the case of aggressive gases and liquids. The flow tube is delivered according to your specific data, e.g. medium, temperature, and pressure.

FM1 - Corrosion resistant, without needle valve, for wall mounting.  Download
FM1 Data Sheet


FM10 - Corrosion resistant, with needle valve, for wall mounting.
Download
FM1 Data Sheet


FM40
- Corrosion resistant, with needle valve for front panel mounting, or optional wall mounting. This compact, flat, corrosion resistant flow meter is used for gas media flow control in analytical devices and systems.
Download
FM40 Data Sheet

Heated Flow Meters:

The FM-1-H and FM-10-H are corrosion-resistant and are used for controlling the flow in the case of aggressive gases and liquids.  The flow tube is delivered according to your specific data, e.g. medium, temperature, and pressure.

FM-1-H - Max. 150C, without needle valve, for wall mounting.
Download
FM1 Data Sheet


FM-10-H
- Max. 150C, with needle valve, for wall mounting.
Download
FM1 Data Sheet


FM-2K
- Max. 200C, without needle valve, for wall mounting.  These are used in analysis technique to control gas flow up to an operating temperature of 180oC. Depending on the flow meter glass tube, ranges from 16 l/h to 800 l/h can be realized. Download
FM200 Data Sheet


FM-200K-H
- Heated up to max. 180C, with needle valve, for wall mounting, power: 230V/50Hz or 115V/60Hz. These flow meters are used in analysis technique to control gas flow up to an operating temperature of 180oC. Depending on the flow meter glass tube, ranges from 16 l/h to 800 l/h can be realized.
Download
FM200 Data Sheet

Flow Alarm Sensors:

The patented forked light-barrier FA1/2/3 bi is used in gas and water analysis for flow monitoring in flow meters with measuring tubes made of transparent material, e.g. Duran glass. Thanks to optical scanning, very low flow can be detected even in flow meters with non-metallic or very small (1 mm) floating balls.

FA1 bi - Suitable for non-heated flow meter FM1/10/40, clamping range 5-14 mm. Download
FA1 Data Sheet


FA2 bi
- Suitable for non-heated flow meters, clamping range 13-27 mm.
Download
FA1 Data Sheet


FA3 bi
- Suitable for non-heated flow meters, clamping range 26-55 mm.
Download
FA1 Data Sheet


FA1-H
- Suitable for heatable or heated flow meters FM-1/10/2/200-H, clamping range 5-14 mm, taking up 2 to 4 light guides. Optical flow-sensor assembly with light guides FO and sensor head FA1-H is used in heated flow meter gas analysis with temperatures greater than 60oC. The FA1-H is used in flow meters with measuring tubes made of light transmitting materials such as Duran glass.
Download
FA1h Data Sheet

 