PRODUCTS - Baghouse Monitors

Back to Products


D-FW 230 - Filter / Baghouse Monitor
D-FW 231 - Filter / Baghouse Monitor
D-FW 235 - Portable Filter / Baghouse Monitor
D-FW 240 - Filter / Baghouse Monitor


D-FW 230
- Filter / Baghouse Monitor

Type:

Filter Monitor with control unit

Description: Filter monitoring based on the tribo-electric measuring principle; Ideal for baghouse monitoring; Continuous in-situ measurement; Compact design Sturdy construction, no moveable parts; Easy, straightforward installation and operation; Fast on-line performance check capability; Minimal maintenance requirements early detection of filter malfunction; Reduces filter replacement costs. 
Applications: Broken bag detector with control unit
Compliance: TV approved for qualitative emissions monitoring 
Measuring range: Qualitative measurement
Flue gas temperature: Above dew point, 200C, higher on request
Measured components: Dust burden
Measuring principle: Tribo electric 
Measuring path: > 0.1 m
Measuring output: 0/4...20 mA analog output
Protection: IP 65
Ambient temperature: -20... +50C
Status/control signals: Relay outputs for status signals
System components: Probe and operating unit
Test functions: Manual zero check
Download: D-FW 230 Brochure 


D-FW 231
- Filter / Baghouse Monitor

Type:

Filter Monitor, probe version

Description: Filter monitoring based on the tribo-electric measuring principle; Ideal for baghouse monitoring; Continuous in-situ measurement; Compact design Sturdy construction, no moveable parts; Easy, straightforward installation; Fast on-line performance check capability; Minimal maintenance requirements early detection of filter malfunction; Reduces filter replacement costs. 
Applications: Broken bag detector
Compliance: TV approved for qualitative emissions monitoring 
Measuring range: Qualitative measurement 
Flue gas temperature: Above dew point, 200C, higher on request
Measured components: Dust burden
Measuring principle: Tribo electric 
Measuring path: > 0.1 m
Measuring output: 0/4...20 mA analog output 
Protection: IP 65
Ambient temperature: -20... +50C
System components: Probe
Test functions: Manual zero check
Download: D-FW 230 Brochure


D-FW 235 - Portable Filter / Baghouse Monitor

Type: Mobile Filter Monitor with three probes, a strip chart recorder and additional accessories in a portable case
Description: This monitoring system consists of a D-FW 231 filter monitor with three probes, a strip chart recorder and additional accessories in a portable case. The system, with overall dimensions of 520x205x460 mm and a weight of 13.5 kg can be easily installed, even in locations that are not very accessible. Three different sensor probes are supplied so that the monitor will be suitable for a wide range of applications. 
Applications: Portable broken bag detector
Compliance: TV approved for qualitative emissions monitoring 
Measuring range: Qualitative measurement
Flue gas temperature: Above dew point, 200C, higher on request
Measured components: Dust burden 
Measuring principle: Tribo electric
Measuring path: > 0.1 m
Measuring output: 0/4...20 mA analog output, connected to built-in recorder 
Protection: Probe IP 65, box with lid closed: IP54
Ambient temperature: -20... +50C
System components: Box with three probe lengths and data recorder 
Test functions: Manual zero
Download: DF-W 230 Brochure


D-FW 240
- Filter / Baghouse Monitor

Type: Filter Monitor for monitoring in hazardous locations
Description: Filter monitoring based on the tribo-electric measuring principle; Ideal for baghouse monitoring in hazardous locations; Continuous in-situ measurement; Compact design Sturdy construction, no moveable parts; Easy, straightforward installation; Fast on-line performance check capability; Minimal maintenance requirements; Early detection of filter malfunction; Reduces filter replacement costs. 
Applications: Broken bag detector in hazardous locations
Compliance: Ex II 2 G/D EEx d ib IIC T6 td A21 ibD21 IP65 T 105C, for zones 1/2 gas, 21/22 dust
Measuring range: Qualitative measurement 
Flue gas temperature: Above dew point, 200C, higher on request
Measured components: Dust burden
Measuring principle: Tribo electric
Measuring path: > 0.1 m
Measuring output: 0/4...20 mA analog output 
Protection: IP 65
Ambient temperature: -20... +50C
System components: Probe
Test functions: Automatic zero check